Skip to content
OGB · Sandwich PanelsInsulated Building Envelope

ShownWall panels as delivered: 1,000 mm cover width, 0.5 mm pre-painted steel skins, 40 – 150 mm insulated core, tongue-and-groove edges

Sandwich Panels · By Application

Wall Sandwich Panels

Flat-faced insulated wall panels with clean concealed joints.

Group
By Application
Market
United Arab Emirates
Supply
Quotation per enquiry

Product overview

Wall Sandwich Panels: overview and uses

Wall sandwich panels have a flat or lightly profiled outer face with a tongue-and-groove or concealed-fix joint, giving a clean, insulated external or internal wall. They are used for building envelopes, partitions, cabins and enclosures.

OGB supplies wall panels with EPS or PU/PIR cores and matching corner, base and top flashings. Thickness, core, colour and length are confirmed per enquiry.

Build your panel

Choose core, thickness and colour

Pick a combination to see its insulation value, then send it to OGB as a quotation request. Every panel is made to order and cut to your length.

1 · Core
2 · Thickness
3 · Outer colour

Colours shown are the common stock RAL shades; other RAL colours, PVDF coatings and different inner/outer colours are available on request. Screen colours are approximate, so confirm against a physical colour card.

Technical data

Specifications

Share your required size, quantity and finish in the enquiry form and OGB confirms availability in writing.

Enquire about Wall Sandwich Panels
Wall Sandwich Panels specifications
Outer skin Pre-painted galvanized steel (PPGI), flat / micro-ribbed
Skin thickness 0.5 mm standard; 0.4 – 0.9 mm available
Core options EPS or PU / PIR
Panel thickness 40, 50, 75, 100, 125, 150 mm (up to 200 mm on request)
Cover width 1,000 mm
Length Cut to order, up to 12 m
Joint Tongue-and-groove, concealed or exposed fix
Standard EN 14509 (self-supporting sandwich panels)

Testing & standards

How Wall Sandwich Panels are tested

These are the test methods and standards that specifiers, civil defence and insurers ask about. Ratings belong to a specific tested system, so OGB supplies the certificate that matches your panel, thickness and joint.

EN 14509
European product standard for self-supporting double-skin metal-faced sandwich panels: dimensions, tolerances, strength, thermal and fire declarations.
EN 13501-1
Reaction-to-fire classification (A1, A2, B … F) of the panel or its core.
EN 13501-2 / EN 1364
Fire-resistance rating of a tested wall or roof system, written as EI 30, EI 60, EI 120 (integrity and insulation, in minutes).
ASTM E84 / UL 723
Surface burning characteristics: flame-spread and smoke-developed indices.
FM 4880 / FM 4881
FM Approvals tests for fire performance and for structural and wind-load performance of insulated panel systems.
NFPA 285
Large-scale fire-propagation test for exterior walls that contain combustible components.
ASTM C518
Laboratory measurement of thermal conductivity and R-value of the insulating core.
ASTM E283 / E331
Air leakage and water penetration through the panel joints under pressure.

Questions

Wall Sandwich Panels: common questions

How thick should a wall sandwich panel be in the UAE?

As a guide: 40 – 50 mm for site offices and sheds, 75 – 100 mm for air-conditioned warehouses and showrooms, and 100 – 150 mm or more for chillers and freezers. The required U-value and the core type decide the final thickness.

Exposed or concealed fixing: what is the difference?

Exposed-fix panels are screwed through the face into the girts, which is quick and economical. Concealed (secret) fix panels hide the screws inside the joint for a clean architectural facade.

Are sandwich panels load-bearing?

No. Sandwich panels span between purlins or girts and carry wind, snow and maintenance loads across that span, but they are not a structural frame. The building still needs a steel or concrete frame, and panel spans are taken from the manufacturer’s load tables.

Why do roof panels cost more than wall panels?

A roof panel has a deep trapezoidal outer skin that uses more steel per square metre and needs a stiffer profile to shed water and carry foot traffic during installation, so the same core thickness costs more on a roof than on a wall.

When should the protective film be removed?

Remove the protective film from the panel faces during or soon after installation, and do not leave panels in direct UAE sun with the film on for long periods. Old, sun-baked film becomes hard to peel and can mark the paint.

Are panels kept in stock?

Panels are made to order: each project needs its own length, core, thickness and colour, so they are produced and cut for the order rather than held as stock lengths.

Free tools · No sign-up

Need quantities for Wall Sandwich Panels?

Free calculator for sandwich panels, fencing, roofing sheets and steel weight. Change a number and the drawing and quantities update live. No prices, no sign-up.

Request a quotation

Request a quotation for Wall Sandwich Panels

Share your drawings, bill of quantities or a simple list of items. OGB confirms sizes, finishes and availability and returns an itemised quotation.